Apply and remeasure¶
Processor-wide field test
Corrections affect all panels on the processor. The SDR/PQ insertion behavior and native-control model still require physical measurement. Numerical results do not establish a qualified stage calibration.
Prepare and apply¶
- Review the baseline analysis and candidate in Results. Use the LUT as the primary route; inspect the separate 14-way/curves residual if considering that alternative. Apply one route at a time.
- Choose Prepare LUT Test or Prepare Native Test, then Continue. Confirm the encoded SDR/PQ domain and baseline bypass state. Native tests also require baseline curves and 14-way correction bypassed during capture.
- Preparation reads the processor and saves a recovery journal. Unreadable backup data or a poor numerical fit blocks replacement.
- Choose Apply Prepared Change, then Continue and confirm. Preparation expires after 60 seconds; reprepare if it expires or the setup changes.
- Wait for matched readback. Use Deployment Details for the full status.
An unknown outcome is not a confirmed failure or a confirmed Apply. Do not retry blindly. Open the saved recovery journal, then prepare Bypass or Restore and confirm its separate Apply action. Restoring a previously empty LUT slot leaves residual bytes disabled because the API cannot delete those bytes.
Capture a linked post-Apply measurement¶
- Keep camera WB, exposure, shutter, lens and position unchanged.
- Choose Remeasure Applied Correction from the baseline run in Results. If needed, use Open Recovery Journal to select the verified Apply journal.
- Studio rereads the correction, native controls, processor identity/project and original input/output setup. This step sends no processor writes.
- On success, Studio saves a separate post-Apply
.ap3drunbeside the original. It retains the original analysis as the baseline and creates an explicit correction/readback link. The baseline run and its captures remain intact. - Generate the new run's patterns and capture/import a fresh sequence after that readback, then analyze it. Imported footage must actually have been recorded after Apply; host import time does not prove camera exposure time.
- Choose Compare Measurements. Studio verifies readback again, then the worker checks the linkage, source hashes, observations and setup before calculating the measured differences.
Results distinguishes recorded correction readback from operator-declared camera continuity. A lower error is an observed difference between the two recordings; changes in exposure/WB or the stage can invalidate attribution. Physical qualification remains a separate check.
For a same-setup repeatability test, use Save Comparison Baseline, New Measurement, acquire new frames and Compare Measurements. The same saved binding is required. Arbitrary cross-setup comparisons remain rejected.